CavStream valve trim lowers cavitation damage by controlling the location and concentration of cavitation vapor bubble implosion in an area away from metal parts. CavStream trim utilizes a number of small, diametrically opposed flow holes through the walls of a special plug.
Additional information
Function | Cavitation Control |
---|---|
Pressure Stages | 1 |
Cv Range | 0.4 to 88 |
Cavitation Sigma Limit | 1.2 |
Trim Design | Plug Integral Cage |
Solids Capable | Yes, small particulate |
Materials | Alloy |
Base Valve | Flowserve Valtek Mark Series |
Valve Size | 1/2" to 3" |
Pressure Class Standard | ASME B16.34 |
Pressure Class Range | Class 150, 300, 600, 900 |
Features & Benefits
- Tolerates Sigma as low as 1.2
- Uses the same technology as CavControl to control cavitation, except the holes are drilled into a special close-guided plug head rather than in the seat retainer
- Impinging jets create a column of cavitation in the center of the plug head, keeping the bubbles away from metal surfaces
- Same performance as CavControl with much lower capacities
- Flow characteristics of trim can be modified through porting size