Products.

Home>Process Solutions
  • The Model 1088 is a valve specifically designed for small tank blanketing applications. It opens and closes automatically as required to maintain a closely controlled blanket pressure. Standard valve material provides added corrosion protection at no additional cost The simple design increases reliability and lowers maintenance cost. 
    Small Tank Blanketing Valve
  • The Model 1078 is a pilot-operated valve specifically designed to reduce blanketing gas losses on low-pressure storage tanks. It opens and closes automatically as required to maintain a closely controlled blanket pressure. The simple design increases reliability and lowers maintenance costs. 
    Pilot-Operated Single Valve
  • The Model 1100 is a stainless steel sanitary vent designed to operate at multiple set points as a breather valve to avoid vacuum or over-pressurization inside a tank or piping system. This unit comes with a true sanitary blanketing connection and is designed so that it can be used with our sanitary blanketing valve; VCI model 1088.  
    Sanitary Quick Vent
  • The Model 4200 pipe-away conservation vent is part of the Valve Concepts, Inc. modular vent product line. The Model 4200 can easily be converted to a vacuum-only vent or end-of-line pressure/vacuum vent and can either be direct-acting or pilot-operated. Only Valve Concepts, Inc. offers complete modularity throughout its complete vent product line. 
    Pressure/Vacuum Spring Loaded Vent
  • The Model 4300 end-of-line spring-loaded vacuum vent is intended for use on storage tanks, vapor recovery systems, and process systems where higher vacuum relief settings are required. 
    End-Of-Line Spring Loaded Vacuum Vent
  • The Model 4400 spring-loaded pressure relief vents are designed for higher pressure settings and are used in applications for normal or emergency venting pressure relief. The series 4400 vents are pressure-only devices and, as such, do not provide vacuum relief. 
    Spring Loaded Pressure Vent To Atmosphere ( OR) Pressure Relief Vent To Atmosphere
  • The Model 4500 spring-loaded pressure vent with pipe away is intended for use where higher set pressures are required, and the relieving vapors must be piped away and not emitted into the atmosphere. May also be used for in-line vacuum relief. 
    Pressure Vent with Pipe-Away
  • The Model 4100 end-of-line spring-loaded conservation vent provides pressure and vacuum relief in applications where higher-pressure settings are required.the model 4100 can easily be field converted to a vacuum-only vent, or a pressure/vacuum vent. 
    End-of Line-Pressure/Vacuum Vent
  • The Model 4600 spring-loaded vacuum relief vents are intended for use on low-pressure tanks, vapor recovery systems, and process systems where higher vacuum relief is required. 
    Side-Mounted Vacuum Relief Vent
  • The Pilot Operated Model 5200 vent provides pressure and vacuum relief in applications that require vapors to be piped away. 
    Pilot Operated Vent with Pipe-Away
  • The Model 5400 is designed for use on atmospheric and low-pressure tanks to reduce environmental emissions and product losses, when operating close to the set point. 
    Pressure Only Relief Vent
  • The Model 5100 end-of-line conservation breather vent is intended for use on atmospheric and low-pressure storage tanks where pressure and vacuum relief is required. 
    End-Of-Line Relief Vent
  • The Pilot Operated Model 5500 conservation pressure vent with pipe-away is intended for use where pressure relief is required and the relieving vapors must be piped away and not emitted into the atmosphere. May also be used for in-line vacuum relief. 
    Pressure Vent w/ Pipe-away Connection
  • The Model 1049 offers the best pilot-operated vent technology on the market today. The unit allows for bubble-tight seat leakage until the pilot starts to exhaust. At that time, the vent starts to open and is fully open at 10% overpressure. Unlike non-pilot operated units that require substantial overpressure in order to obtain full lift. On Model 1049, the blowdown is limited, and the valve reseats at the set point, where the non-pilot-operated units will go below the set point in order to reseat. 
    Pilot Operated Vent Valve
  • The Model 3K00 Pressure / Vacuum Vent is designed for use on atmospheric and low-pressure storage tanks where pressure and vacuum relief are required. Weight-loaded pallets in the vent housing allow the intake of air and the escape of vapors as the tank breathes due to thermal changes and product movement in and out of the tank. The pallets open and close to permit in-breathing and out-breathing necessary to maintain the tank pressure within permissible limits to avoid damage to the tank. 
    Pallet assembly Pressure / Vacuum Vent
  • The Model 6K00 Pressure / Vacuum Vent with Flame Arrestor is designed for use on atmospheric and low-pressure storage tanks where pressure and vacuum relief are required. The model 6K00 is used as an independent safety system to ensure explosion protection. 
    Pressure / Vacuum Vent with Flame Arrestor
  • The Model 3300 end-of-line conservation breather vent is part of Valve Concepts, Inc. modular vent product line. The Model 3300 can easily be field converted to an end-of-line pressure/vacuum relief vent with the addition of weather hood components or an in-line pressure/vacuum relief with the addition of pipe away body components. 
    Top Mounted Vacuum Relief Vent
  • The Flowserve Logix Zero-Bleed automation package is a comprehensive solution designed to help eliminate emissions in accordance to industry regulations governing steady-state bleed from pneumatic devices. The 3800zb control unit, which serves as the heart of the Zero Bleed Automation Package, brings simplicity and effectiveness to process control. It leverages the advanced features of the 3800 Smart Positioner device and integrates a zero-bleed system to achieve emissions reduction during steady-state positioning.  
    Zero Bleed Smart Digital
  • Goodwin’s Axial Isolation Valves can be operated fully open to fully closed or vice-versa in less than 2 seconds. This is compared to a ball valve which usually requires 1 second per inch of bore to do the same operation. The streamlined flow path through an Axial Isolation Valve has minimal pressure drop. The flow is directed through the valve to avoid critical sealing areas, promoting the longevity of the sealing arrangement. This valve has a bi-directional flow because of the pressure-energized seals, bubble-tight shut-off is achieved in both directions.   Actuation Options Include: 
    • Manual Operation
    • Pneumatic
    • Hydraulic
    • Electric
    • Electro-hydraulic
    Axial Isolation Valve
  • Goodwin’s streamlined flow path through an Axial Control Valve has minimal pressure drop. The flow is directed through the valve to avoid critical sealing areas, promoting the longevity of the seat sealing arrangement. With an annular flow area and an unrestricted, symmetrical, streamlined flow path through the valve, Axial Control Valves have a higher inherent flow capacity compared to conventional globe control valves.   Actuation Options Include: 
    • Manual Operation
    • Pneumatic
    • Hydraulic
    • Electric
    • Electro-hydraulic
    Axial Control Valve